Home / Case Studies / Sloped Roof Home Elevator
Non-Standard Elevator Case Study

Custom Home Elevator Engineering for a 2.5 m Sloped Roof.

A customized residential elevator solution developed for a three-story private residence in Changyuan City, where the lowest point of the sloped roof is only 2.5 meters.

2.5 m Roof Height 3-Story Residence Traction Gantry Structure Non-Standard Design
Non-standard home elevator design for a private residence with a sloped roof
Critical Site Condition 2.5 m Lowest point of the sloped roof
Project Type Private Residential Elevator
Building Three-Story Private House
Main Constraint Sloped Roof / 2.5 m Lowest Point
Solution Customized Traction Gantry Structure
Project Background

When the building does not fit a standard elevator.

Henan Shumeida Elevator Co., Ltd. completed a customized residential elevator installation for a three-story private residence in Lucan Village, Changyuan City.

The upper floor of the building features a sloped roof. After on-site measurements, the installation team confirmed that the lowest point of the roof was only 2.5 meters.

This created a typical space-limited installation condition in which a conventional home elevator configuration could not be directly applied.

The solution had to adapt to the house.

Instead of forcing the building to accommodate a standard layout, the technical team developed a non-standard elevator configuration around the actual site dimensions and structural conditions.

Engineering Challenge

Restricted space at the top floor.

The sloped roof created an uneven overhead condition. The elevator structure, traction arrangement and component positioning therefore required a project-specific solution rather than a conventional standardized layout.

01

2.5 m Lowest Roof Point

The available vertical space at the upper floor was insufficient for a conventional elevator configuration.

02

Sloped Roof Geometry

Available overhead varied across the installation area, requiring careful structural and equipment positioning.

03

Limited Residential Space

Equipment arrangement also needed to reduce its impact on usable indoor space and simplify future maintenance.

Customized traction home elevator installation for sloped roof residence
Non-standard residential elevator installation Designed around the actual building structure and roof conditions.
Technical Solution

A non-standard traction layout.

To solve the restricted overhead condition, the technical team adopted a non-standard configuration combining a traction gantry structure elevator with a heavy-duty side-mounted layout. The objective was to make effective use of the available building space while maintaining structural rigidity and stable elevator operation.

01

Traction Gantry Structure

The elevator uses a traction gantry structural configuration specifically adapted to the restricted installation environment of the residence.

02

Heavy-Duty Side-Mounted Layout

A side-mounted arrangement helps coordinate the elevator components with the actual hoistway and the unusual roof geometry.

03

Solid T78 Rails

Both the main rail and guide rail use solid T78 rails, selected to improve load-bearing performance, structural stability and service life.

04

Belt Load-Bearing Transmission

The belt transmission structure helps reduce operating noise, distribute stress and improve load capacity and durability.

Core Configuration

Engineered for rigidity, stability and space efficiency.

Key components and installation decisions were selected around the actual structural and spatial limitations of the residence.

Roof Condition 2.5 m Lowest Point

Sloped upper-floor roof.

Main Rail Solid T78 Rail

Selected for higher load-bearing capability and durability.

Guide Rail Solid T78 Rail

Used together with the main rail for improved structural stability.

Transmission Belt Transmission

Load-bearing configuration designed for quieter operation and stress distribution.

Traction Machine Base 20 mm Base Plate

Installed beneath the traction machine at the top of the hoistway.

Control System Monarch 9000

Used for speed regulation and elevator safety control.

T78 solid rail and structural details of non-standard residential elevator
Structural Reinforcement

Solid T78 rails instead of hollow rails.

Both the elevator main rails and guide rails use solid T78 rails. Compared with ordinary hollow rails, this configuration improves load-bearing capacity and service life while supporting stable elevator operation.

✓
Improved Load-Bearing Capacity Solid rail construction provides greater structural strength.
✓
Longer Service Life Robust rail construction supports long-term elevator use.
✓
Strong Rail Brackets Main and guide rail brackets reinforce overall rigidity and deformation resistance.
Traction & Control

Compact installation. Practical maintenance.

The traction machine is positioned at the top of the hoistway with a 20 mm thick base plate underneath. The control cabinet is installed at the rear of the hoistway to reduce the use of interior space and make future inspection and maintenance easier.

Traction Machine Top-Mounted in Hoistway
Base Plate 20 mm Thick
Control System Monarch 9000
Control Cabinet Rear of Hoistway
Traction machine and control arrangement for custom residential elevator
Installation Quality

Controlled from rail installation to commissioning.

During installation, the technical team controlled each procedure from guide rail mounting accuracy through final control system commissioning.

01

Site Measurement

Actual building dimensions and roof conditions are verified before installation.

02

Rail Installation

Rail alignment and mounting accuracy are carefully controlled.

03

Structural Installation

Gantry structure, brackets and traction components are installed according to the project layout.

04

System Commissioning

The control system is commissioned after the mechanical installation is completed.

Project Value

A practical solution for space-limited homes.

This project demonstrates the value of non-standard elevator engineering when conventional residential elevator layouts cannot be directly applied to the building.

Adapted to Restricted Space

The elevator configuration was developed around the 2.5 m sloped-roof limitation.

Reinforced Structure

Solid T78 rails and robust mounting brackets strengthen the overall structural system.

Quieter Transmission

Belt transmission helps reduce operating noise while distributing load stress.

Space-Efficient Control

Rear-mounted control cabinet reduces its impact on the usable indoor space of the residence.

Custom Home Elevator Project

Have a difficult installation space?

Send us your floor plan, site photos and available installation dimensions. Our technical team can review the building conditions and discuss a suitable elevator configuration for your project.

Helpful information for initial review:
  • Available shaft width and depth
  • Floor-to-floor heights
  • Pit depth
  • Available overhead height
  • Number of floors and stops
  • Site photos or architectural drawings

Request a Project Review

Tell us about your building and installation conditions.

    We use your details to respond to this inquiry.

    This page presents an actual customized elevator application case. Final dimensions, structure, components and installation requirements for other projects must be confirmed according to site conditions and approved technical drawings.
    Scroll to Top