Home / Case Studies / Ruzhou Home Elevator Shaft Optimization
Shaft Dimension Deviation Case

Home Elevator Solution After a 200 mm Shaft Depth Loss.

A technical optimization case for a three-story self-built house in Ruzhou, Henan, where construction changes reduced the elevator shaft depth from 1.6 m to only 1.4 m.

Original Shaft 1.84 × 1.6 m Final Depth 1.4 m 200 mm Beam Displacement Traction Elevator Adaptation
Technical optimization for elevator shaft in three-story self-built house in Ruzhou Henan
Shaft Depth Change 1.6 → 1.4 m 200 mm lost during structural construction
Building Type Three-Story Self-Built House
Original Shaft 1.84 × 1.6 m
Actual Depth 1.4 m
Optimization Customized Traction Solution
Project Background

The shaft was planned correctly — then construction changed it.

This project is located in Ruzhou, Henan and involves a three-story self-built residence with an elevator position reserved in the center of the staircase.

The original elevator shaft reservation measured approximately 1.84 meters in width and 1.6 meters in depth.

During construction, however, the structural beams on the second and third floors were moved inward by approximately 200 mm. As a result, the usable front-to-back depth of the elevator shaft was reduced to only 1.4 meters.

A 200 mm structural deviation can change the entire elevator solution.

Small changes to beams or shaft dimensions during civil construction can significantly affect the available elevator installation space and final equipment configuration.

Construction Deviation

The second and third floor beams moved inward.

Although the ground-level shaft reservation was suitable, structural changes on the upper floors reduced the effective shaft depth and created a non-standard installation condition.

01

Original Shaft Was Suitable

The reserved 1.84 × 1.6 m shaft provided a practical starting condition for a residential elevator.

02

Beam Position Changed

Second- and third-floor structural beams were moved inward by approximately 200 mm.

03

Usable Depth Reduced

The effective front-to-back shaft depth was reduced from 1.6 m to 1.4 m.

Elevator shaft with dimensional deviation caused by structural beam position
Existing elevator shaft after structural construction On-site measurement was required to determine the actual usable installation space.
On-site measurement of reduced home elevator shaft depth
Dimension Diagnosis

Measure the actual shaft, not the original drawing.

Once the building structure is completed, elevator selection must be based on the real finished dimensions rather than the original construction plan.

The technical team therefore re-measured the shaft on site, identified the depth loss caused by the beam displacement, and evaluated its impact on elevator installation.

Original Width 1.84 m
Original Depth 1.60 m
Actual Depth 1.40 m
Depth Reduction 200 mm
Key Project Dimensions

One structural change. A different elevator design condition.

The technical proposal had to be adjusted to the completed shaft rather than relying on the originally reserved dimensions.

Original Shaft Width 1.84 m

Left-to-right reserved shaft width.

Original Shaft Depth 1.60 m

Planned front-to-back installation depth.

Beam Movement 200 mm

Upper-floor beams moved inward during construction.

Final Usable Depth 1.40 m

Actual front-to-back depth available for elevator optimization.

Technical Diagnosis

Identify the cause before changing the elevator.

The site survey was used to determine exactly where the shaft dimension had changed and how that change affected the available elevator installation space.

✓
Actual Shaft Measurement Finished dimensions were rechecked after civil construction.
✓
Beam Position Verification Structural beam displacement was identified as the source of the depth loss.
✓
Installation Impact Review The reduced dimension was evaluated against residential elevator requirements.
✓
Solution Re-Matching Elevator configuration could then be adapted to the actual available space.
Technical diagnosis of home elevator shaft dimensional deviation
Customized Optimization

Adapt the elevator to the shaft that actually exists.

With the shaft depth reduced to 1.4 m, the solution needed to make more efficient use of the remaining space rather than simply applying the original elevator configuration.

01

Traction Solution Matching

A traction home elevator configuration can be adapted around the reduced shaft dimensions.

02

Maximize Shaft Utilization

Equipment and structural arrangement are optimized to make better use of the remaining available depth.

03

Maintain Practical Use

The revised proposal still needs to support practical residential elevator functionality.

04

Keep Safety First

Space optimization must remain within a technically suitable and safe elevator configuration.

Problem-Solving Process

Measure. Diagnose. Re-match. Optimize.

Existing shaft problems should be solved from actual measurements rather than assumptions based on the original drawings.

01

Measure the Shaft

Confirm actual finished width, depth and structural conditions.

02

Identify the Deviation

Determine where civil construction differs from the intended design.

03

Match a New Solution

Select an elevator configuration around the actual available space.

04

Confirm Installation

Finalize the technical solution before equipment production and installation.

Prevent the Same Problem

Build according to the approved elevator drawings.

This case also shows why elevator shaft drawings should be followed carefully during the construction of a self-built house.

01 Fix Shaft Dimensions Early

Confirm elevator dimensions before structural work progresses.

02 Control Beam Positions

Avoid changing structural beams without checking their impact on the elevator.

03 Follow Approved Drawings

Civil construction should match the confirmed elevator-shaft design.

04 Verify Before Finishing

Recheck the shaft before later construction makes correction more difficult.

Shaft Dimension Problem?

Your completed shaft is smaller than originally planned?

Send us the actual shaft dimensions, floor plans and site photos. We can review the completed structure and discuss whether the elevator configuration can be optimized around the available space.

Useful information for initial review:
  • Actual shaft width and depth on every floor
  • Original construction drawings
  • Beam and column positions
  • Door opening dimensions
  • Pit and overhead conditions
  • Number of floors and stops
  • Site photos or videos

Request a Shaft Optimization Review

Send us your actual dimensions and existing shaft conditions.

    We use your details to respond to this inquiry.

    This page presents an actual residential elevator shaft optimization case. Final elevator dimensions, configuration and installation feasibility must be confirmed according to actual site measurements and approved technical drawings.